Page 29 - InertexCatalog2010

SEO Version

G:\DOCSINER\Inertex Files\ADVERTIZ\REDBOOK\JSTECHR4.DOC 4/26/02
4
ADDITIONAL TESTING INFORMATION
Mass change after storage in synthetic gas condensate and subsequent drying out.
Testing Conditions
Original Samples
Compressed Samples
Soaking in Isooctane/Toluol
(70/30), 7 days at 23
°
C.
62
1.3
Drying out, 14 days at 40
°
C
-0, 1
-0, 1
Soaking in
Isooctane/Toluol/Methanol
(50/30/20) 7 days at 23
°
C
64
1.2
Drying out, 14 days at 40
°
C
-0, 1
0, 0
APPLICATION INFORMATION
Size Conversion:
1mm
1/8”
3/16”
1/4”
3/8”
1/2”
5/8”
3/4”
1”
1mm
3mm
5mm
7mm
10mm
14mm
17mm
20mm
25mm
Size Recommendation: *
Nominal Pipe Size (ANSI B16.5)
Recommended Size of
INERTEX
Ò
UHF Joint Sealant
1/2”, 3/4”
1/8”
1”, 1-1/4”, 1-1/2”
3/16”
2”, 2-1/2”, 3”, 3-1/2”
1/4”
4” - 6”
3/8”
8” - 16”
1/2”
18” - 20”
5/8”
24” - 36”
3/4”
36” - 60”
1”
60” and over
2”
Other Nonstandard Flanges
Sealing Width
Recommended Size of
INERTEX
Ò
UHF Joint Sealant
1/8” - 1/4”
1/8”
5/16” - 3/8”
3/16”
7/16” - 5/8”
1/4”
3/4” - 1”
3/8”
1 1/8” - 1 1/2”
1/2”
1 5/8” - 2”
5/8”
2” - 2 1/2”
3/4”
2 1/2” -5”
1”
5” over
2”
* In case of non-standard flanges, damaged flanges, or bigger than 24”, the size recommended is 1/2 of the