Operating Parameters
Temperature Range
-450
o
F to +600
o
F
Pressure Range
Full vacuum to 3000 PSI
Chemical Compatibility
Fully compatible throughout the pH range of 0 to 14!
Affected only by elemental Fluorine and molten alkali
metals.
Oxygen Service Limits
Oxygen index of 94.5% (PRODUCT MUST BE ORDERED
WITHOUT ADHESIVE STRIP) (PTFE will burn in 100%
oxygen atmosphere when ignition source is provided)
FDA Suitable
FDA 21CFR 177.1550
Material Properties
A.
Specific Gravity: 0.45 - 0.55 for UHF Joint Sealant; 0.75 - 0.95 for SQ-S Gasket Sheet;
compressed to 2.0 - 2.1
B.
Modulus of Elasticity: 50,000 PSI at 73
°
F
C.
Matrix Tensile Strength:
£
6800 PSI
D.
Coefficient of Friction: 0.2 (comparable to wet ice)
E.
Surface Free Energy: 18.5 dynes / cm
2
.
F.
Chemical Compatibility: Inert except with elemental fluorine and alkali metals.
G.
0xygen Index: 94.5%
H.
Thermal Conductivity: 0.601 BTU-in/hr-ft
2
-
°
F @ 75
°
F
I.
Heat of combustion: 1434
±
100 cal/g
J.
Specific heat: 0.23 BTU/lb. -
°
F
K.
Autoignition Temp: 939
±
100
°
F
L.
Ignition Temp.: Pa = 75 bar 145
°
C = 12k, Pe = Approx. 105 bar in condensed oxygen.
M.
Dissociation Pressure: 5 x 10
-18
mm Hg at 27
°
C: 5 x 10
-12
mm Hg at 100
°
C.
N.
PTFE is degraded by high energy radiation; however, there are examples of exposure
to 17 megarads of gamma radiation on steel flanges with no loss of seal.
O.
Toxicity: NON-TOXIC
P.
HEALTH HAZARDS: None under normal use and conditions
Q.
WASTE DISPOSAL METHOD: Normal landfill - complies with any local disposal
regulations