A-7
Styles 8093 DSA,
8094 DSA
Superior performance
¦
Patented cup and cone rings expand radially to
form a positive seal against both shaft and box
bore
¦
Requires less axial force to effect a seal
¦
Withstands a wide range of chemicals
Reduced costs
¦
Reduced equipment wear and maintenance
¦
Flexible graphite rings conduct heat away from the
shaft, so equipment runs cooler and longer
¦
Signifcant reduction in leakage
Versatile
¦
Style 8093 DSA for service in clean media
¦
Style 8094 DSA with split lip seal for abrasive
service
Gasket spacer (Style 3530 or G-9900)
Braided ring (Style 98, 1304, 5000 or 8921-K)
Low density GRAPH-LOCK
®
preforms
High density GRAPH-LOCK
®
adapters
* Depends on braid choice
Model 26 lip seal
Gasket spacer (Style 3530 or G-9900)
Braided ring (Style 98, 1304, 5000 or 8921-K)
Low density GRAPH-LOCK
®
preforms
High density GRAPH-LOCK
®
adapters
8093 DSA Specifcations
Construction:
Typical set: gasket spacer, braided
rings, fexible graphite adapters and
preforms
Media:
Condensate, boiler feed water, light
paper stock, white water, feed water
Temperature:
To +500°F (+260°C)
pH range:
0-14* (except strong oxidizers)
Shaft speed:
To 4,000 fpm plus (20 m/s)
Pressure:
To 500 psi (35 bar)
8094 DSA Specifcations
Construction:
Typical set: Model 26 lip seal,
gasket spacer, braided rings,
fexible graphite adapters and
preforms
Media:
Abrasive service
Temperature:
To +200°F (+93°C)
pH range:
2-12*
Shaft speed:
To 4,000 fpm plus (20 m/s)
Pressure:
To 300 psi (20 bar)