Page 39 - GarlockFluidSealing2010

SEO Version

B-7
Movement Capabilities
Control Units
Control units must be used to protect expansion
joints from excessive movement if piping is not properly
anchored. See page B-19 for information.
Fully Tested and Field Engineered
All Garlock expansion joint styles have been rigor-
ously lab- and feld-tested, and engineered to ensure
long life and reliable service.
*OINT -OVEMENT INCHES
&ORCE LBS
0IPE 3IZES
*OINT -OVEMENT INCHES
&ORCE LBS
0IPE 3IZES
Notes:
1. Sizes 3"-20" indicate nominal ANSI pipe sizes.
2. 3" and 4" I.D. have 3/4" maximum compression and 3/8" maximum
elongation.
3. Forces to compress and elongate are based on zero pressure condi-
tions and ambient temperatures in the pipeline.
4. To convert force in pounds to kilograms, divide by 2.205.
5. Metric sizes avilable by special request.
Compression
Elongation
Pipe I.D.
Movement
Type Movement
Inch
mm
Inch
mm
Compression
3-4
75-100
3/4
19
6-20
150-500
1
25
Elongation
3-4
75-100
3/8
10
6-20
150-500
1/2
12
Lateral
3-4
75-100
1/2
12
6-20
150-500
1/2
12
Pipe I.D.
Movement
Type Movement
Inch
mm
Degrees
Angular
3-4
75-100
8
6-8
150-200
5
10-12
250-300
4
14-16
350-400
2.5
18-20
450-500
2
Torsional
3-12
75-300
3
14-16
350-400
2
18-20
450-500
1