Ordering Guide
Heat Exchanger
The size restrictions for heat exchanger gaskets
depend only on the available sizes of the materi-
als. Heat exchanger gaskets are commonly made in
diameters up to 120", with rib widths up to 1-1/4" and
thicknesses up to 1/4".
When ordering, specify:
¦
Style number
¦
Shape (Give confguration code, page D-13)
¦
Thickness
¦
Material (metal or metal and fller)
Plus specify (according to diagram below):
1. Outside diameter
2. Inside diameter
3. Rib width
4. Radius of rib
5. Bolt circle radius
6. Distance from center line of gasket to center line of
ribs
7. Radius around bolt
8. Size and number of bolt holes
Note:
In addition to the above information, drawings of your application
are always helpful in proper dimensioning of gaskets.
RW, RWI Spiral Wound
When ordering, specify:
¦
Nominal pipe size or gasket dimensions, and pres-
sure class
¦
Winding and fller materials
¦
Centering and/or inner compression ring material
SW Spiral Wound
When ordering, specify:
¦
OD and ID dimensions (and tolerance, if other than
standard—see page D-19)
¦
Thickness of gasket
¦
Winding and fller material
¦
Inner ring material, if required (Style SWI)
¦
Pressure rating
HH, MC and MCR Manhole
When ordering, specify:
¦
Make and model of boiler and/or equipment if avail-
able (See chart page D-10)
¦
Gasket style and confguration
¦
Dimensions of gasket (thickness, fange seating
width, and shape)
¦
Maximum operating pressure and temperature
¦
Type of metal and fller materials
Custom Gaskets
A spiral wound gasket can be made to almost any
dimension required. Possible designs include multiple
windings and rings, with combinations of different fllers
or special winding materials and ring shapes. Describe
your application or send us a drawing and we’ll help
you design the appropriate winding.
WARNING:
Properties/applications shown throughout this brochure are typical. Your specifc applica-
tion should not be undertaken without independent study and evaluation for suitability.
For specifc application recommendations consult Garlock. Failure to select the proper
sealing products could result in property damage and/or serious personal injury.
Performance data published in this brochure has been developed from feld testing,
customer feld reports and/or in-house testing.
While the utmost care has been used in compiling this brochure, we assume no respon-
sibility for errors. Specifcations subject to change without notice. This edition cancels
all previous issues. Subject to change without notice.