D-22
Maximum Flange Bore
for FLEXSEAL
®
Gaskets
Flange
Size
Pressure Class
(NPS)
75
150
300
400
600
900
1
1500
1
2500
1
1
/
2
"
Weld-neck
3
/
4
"
Weld-neck only
2
only
2
1"
Weld-neck
1
1
/
4
"
Slip-on
3
No fanges.
Slip-on
3
No fanges.
only
2
Weld-neck
2
Use Class
Weld-neck
2
Use Class
1
1
/
2
"
No
600
1500
recommen-
2"
dation
Slip-on
3
Slip-on
3
in
Weld-neck,
Weld-neck,
2
1
/
2
"
75 lb.
any bore
any bore
fanges
Slip-on, Weld-
3"
neck, any bore
Weld-neck with
Standard wall bore
4"
(includes nozzle
4
but
excludes Slip-on)
6"
Weld-neck with
Schedule 10S bore
8"
described in ASME B36.19M
Weld-neck w/
(includes nozzle
4
but
Schedule 60
10"
excludes Slip-on)
bore
Slip-on,
Weld-neck w/
12"
Weld-neck, any bore
Schedule 80
bore
14"
Weld-neck w/
Weld-neck with
Standard wall
16"
Schedule 10 bore
bore
described in ASME B36.10M
(excludes No fanges
18"
(excludes nozzle
4
nozzle and
and Slip-on
5
)
Slip-on)
20"
Weld-neck w/
24"
Sched. 40 bore
Notes:
1. Inner rings should be used for Class 900 gaskets, NPS 24; Class
1500 gaskets, NPS 12 thru NPS 24; and Class 2500 gaskets, NPS 4
thru 12 (see ASME B16.5, 3.2.5). These inner rings may extend into
the pipe bore a maximum of 0.06" (1.5 mm) under the worst combina-
tion or maximum bore, eccentric installation, and additive tolerances.
Purchaser should specify inner ring material.
2. In these sizes the gasket is suitable for a weld-neck fange with a
standard wall bore, if the gasket and the fange are assembled con-
centrically. This also applies to a nozzle. It is the user’s responsibility
to determine if the gasket is satisfactory for the fange of any larger
bore.
3. Gaskets in these sizes are suitable for slip-on fanges only if the
gaskets and fanges are assembled concentrically.
4. A nozzle is a long welded neck; the bore equals the fange NPS.
5. An NPS 24 gasket is suitable for nozzles.
WARNING:
Properties/applications shown throughout this brochure are typical. Your specifc applica-
tion should not be undertaken without independent study and evaluation for suitability.
For specifc application recommendations consult Garlock. Failure to select the proper
sealing products could result in property damage and/or serious personal injury.
Performance data published in this brochure has been developed from feld testing,
customer feld reports and/or in-house testing.
While the utmost care has been used in compiling this brochure, we assume no respon-
sibility for errors. Specifcations subject to change without notice. This edition cancels
all previous issues. Subject to change without notice.