Suggested Pipe Size for Compressed Air Flow
at 100 PSI Length of Run, Feet
On a compressed air distribution system, pressure losses greater than 3% are considered excessive, and a well-designed
system having a steady rate of air flow is usually designed for not more than a 1% loss or 1 PSI for a 100 PSI system. The pipe
size depends not only on the volume of air flow but how far it must be carried. To hold the distribution loss to 1 PSI, pipes of
larger diameter must be used on longer runs to carry the same flow that can be handled by smaller pipes on shorter runs.
Figures in the body of the chart above are pipe sizes recommended on a 100 PSI system to carry air with less than 1 PSI loss.
When measuring lengths of runs, add 5' of length for each pipe fitting. If carrying 120 PSI pressure these sizes will carry slightly
more air than shown, or pressure loss will be slightly less than 1 PSI. If carrying 80 PSI pressure these pipes will carry slightly
less air at 1 PSI pressure loss than shown in the chart.
The left column of the chart shows the volume of air to be carried. It is difficult to estimate the air flow volume to be carried in
each leg of the distribution system. This varies with the application. On some applications, like in a large plant with many legs in
the distribution system serving dozens of air-operated machines, the air usage may be at a fairly steady rate. Other applications,
usually on small systems, may have to carry a high surge of air if several machines happen to be operated at the same time.
Then there may be a period with almost no flow.
To make a realistic estimate of air flow volume, the far right column of the chart showing compressor HP may be used. On
steady pumping, a compressor will produce a minimum of 4 SCFM air flow for each 1 HP of capacity. This is a conservative
figure, as most compressors will produce 5 or 6 SCFM.
For example, a 25 HP compressor will produce at least 100 SCFM of air as shown in the far left column on the same line as
25 HP.
excerpted from
Industrial Fluid Power
, Volume 1, third edition, 1984
SCFM
Air Flow
25
50
75
100
150
200
300
500
1000 Compressor
HP
4
12
20
30
40
60
80
100
120
160
200
240
300
400
500
½
½
¾
¾
¾
1
1
1¼
1¼
1¼
1½
1½
2
2
2
½
½
¾
¾
1
1
1¼
1¼
1½
1½
2
2
2
2½
2½
½
½
¾
1
1
1¼
1¼
1½
1½
1½
2
2
2
2½
2½
½
¾
¾
1
1
1¼
1¼
1½
1½
2
2
2
2½
2½
3
½
¾
1
1
1¼
1¼
1½
1½
2
2
2
2½
2½
3
3
½
½
¾
1
1
1¼
1¼
1½
1½
1½
2
2
2
2½
2½
½
¾
1
1¼
1¼
1½
1½
2
2
2½
2½
2½
3
3
3½
¾
1
1¼
1¼
1½
1½
2
2
2½
2½
3
3
3
3½
3½
¾
1
1¼
1¼
1½
2
2
2½
2½
3
3
3
3½
4
4
1
3
5
7½
10
15
20
25
30
40
50
60
75
100
125