375
Appendix
Appendix
Installation & Maintenance
Assemblies
Equipment & Accessories
Fittings
Hoses
Chemical Resistance Tables
The following is a representative list of fluids and manufacturers and a general guideline for
the use and compatibility of Continental ContiTech hose and fittings.
Hose
Fittings and Adapters
Chemical Name
PTFE
(
Teflon®)
CR
(
polychloropene)
NBR
(
Nitrile)
Nitrile/
PVC
CPE
CSM
Urethane
Nylon
Carbon
Steel
Stainless
Steel 304
Stainless
Steel 316
Aluminum
Brass
Linseed Oil
E
X
E
-
-
-
-
E
E
E
E
G
G
Linseed Oil (Boiled)
G
G
E
E
E
E
-
G
E
E
E
G
LPG
Lubricating Oil (Diester
Under 135°F)
X
G
X
-
-
X
E
E
E
E
E
E
Lubricating Oil (Petroleum
Base)
E
G
E
G
E
G
G
E
E
E
E
E
E
Lubricating Oil (SAE 10, 20,
30, 40, 50)
E
G
G
-
-
-
-
E
E
E
E
E
-
Machine Oil (Under 135°F)
E
E
E
G
-
G
G
-
E
E
E
E
E
Magnesium Carbonate
E
E
E
E
-
E
E
-
G
G
G
E
-
Magnesium Chloride
E
E
E
E
E
E
E
E
X
G
E
X
G
Magnesium Hydroxide
E
G
G
G
E
E
X
-
E
E
E
X
X
Magnesium Nitrate
E
G
G
G
-
E
-
-
G
G
G
X
E
Magnesium Sulfate
S
G
G
G
E
E
E
E
G
G
G
G
G
Malation (Ag Spray Dilute)
-
G
-
-
-
-
E
E
E
E
-
E
Maleic Acid
E
G
X
-
-
-
-
E
-
E
E
G
G
Manganese Salts ( to 70°F)
E
-
E
E
-
E
-
-
-
-
-
-
-
Maximul (Penzoil Hydraulic
Fluid)
G
E
G
-
-
-
-
E
-
E
-
-
Mercuric Chloride
E
E
G
G
E
E
G
X
X
G
G
X
X
Mercuric Cyanide
E
E
G
G
-
E
-
-
G
G
G
X
-
Mercurous Nitrate (Under
120
°F)
E
E
G
G
-
E
-
-
E
E
E
X
-
Mercury
E
E
G
G
E
E
G
E
E
E
E
X
X
Mesityl Oxide
E
X
X
X
G
X
X
-
E
E
E
E
E
Methane (Gas or Liquid )
E
G
E
-
-
-
-
-
-
E
E
-
-
Methanol
Methoxychlor (Insecticide)
-
-
-
-
-
-
X
E
E
E
-
-
Methyl Acetate
E
X
X
X
E
X
-
-
E
E
E
E
E
Methyl Acrilate
E
X
X
X
-
X
-
-
E
E
E
E
E
Methyl Alcohol, Methanol
E
Methyl Amine (25% Aque-
ous Solution
E
G
X
-
-
-
-
-
E
E
E
E
-
Methyl Amine (60%)
G
G
-
-
-
-
G
E
E
E
E
G
Methyl Amine (99%)
X
X
-
-
-
-
-
E
E
E
E
X
Methyl Amyl Carbinol
E
-
-
-
E
-
-
-
E
E
E
-
-
Methyl Bromide
E
X
X
X
-
X
X
X
E
E
E
X
E
Methyl Butyl Ketone (MBK)
E
X
X
X
G
X
-
-
E
E
E
E
E
Underline is cover compound rating only. Many factors, such as temperature, concentration and length of exposure, are relevant to how chemical exposure affects the tube and
cover or fitting material. The fluid manufacturers recommended maximum operating temperature should be carefully observed. Exceeding the manufacturer's recommended
maximum temperature can result in fluid breakdown and cause harm or shorten life of tube and cover materials. There may be instances where the hose cover could be adversely
affected by fluids which would not chemically affect the hose tube. Conversely, some fluids with an adverse affect on the tube of the hose may not have a deteriorating effect on
the hose cover. It is recommended that the user test the hose/fluid compatability to their own standards. Since no industry standards exist for chemical resistance, the Compass
Chemical Resistance Guide for Elastomers is used whenever possible. Teflon® is a registered trademark of Dupont.
Rating Scale
E
= Excellent resistance
G
= Good resistance
X
= Not recommended
-
= Testing recommended
Blank
= No Data